A6 Quattro Sedan V6-3.2L (BKH) (2005)
soon becomes saturated with moisture and thus unusable when reservoir is open).
‹› In case e.g. of an accident with the refrigerant, clean the refrigerant circuit if an unknown amount of refrigerant oil leaks out or dirt or moisture
enters the circuit (irrigate).
‹› Connection at reservoir can be marked with "IN" (from evaporator) and "OUT" (to compressor).
Installation is carried out in the reverse order, when doing this note the following:
-
Insert reservoir - E - in bracket - G -; note the anti-twist and secure mounting element - J -.
-
Tighten the screws - D -.
‹› Tightening specification: 10 Nm.
-
Place washer - C - on bolt - H -.
-
Install the reservoir - E - with the bracket - G -.
-
Insert the screws - A - and nuts - B -.
‹› Tightening specification: 10 Nm.
-
Replace O-rings - D - and - E -.
-
Check the guide ring - H - on the connections for both refrigerant lines - B - and - C - for damage.
-
Insert the respective O-ring seal (- D - and - E -) in the groove - J - on the connections for both refrigerant lines - B - and - C -.