Refrigerant Pressure Sensor / Switch: Service and Repair

A/C Pressure/Temperature Sensor G395, Removing And Installing

NOTE:

-

Cooling output cannot be checked with A/C Pressure/temperature Sensor G395 removed. Control and display unit, Climatronic Control Module
J255 does not switch on compressor.

-

Refrigerant circuit remains closed (connection with valve).

-

Measured values of A/C Pressure/temperature Sensor G395 can be read out by way of function "Read Measuring Value Block" (display group
"001") and "Guided Fault Finding" function of Diagnostic operation system/Vehicle diagnosis service system VAS 5051 A/5052.

-

A/C Pressure/temperature Sensor G395 exchanges information by way of air conditioner data bus system "Local Interconnect Network (LIN-Bus)"
with control and display unit, Climatronic Control Module J255 (Read Measuring Value Block, display group "054") and "Guided Fault Finding"
function of Diagnostic operation system/Vehicle diagnosis service system VAS 5051 A/5052.

-

On account of the design of the A/C Pressure/temperature Sensor G395 and its component location, temperature measured by A/C
Pressure/temperature Sensor G395 differs from actual temperature of refrigerant. At present this is therefore not evaluated and used for air
conditioner regulation.

-

Audi A6 is only to be installed with A/C Pressure/temperature Sensor G395 (housing color "Grey") Parts List.

-

Audi A6 is not to be installed with High Pressure Sensor G65 (housing color "Black") (only emits square-wave signals) Parts List.

Removing and installing

-

Remove front bumper cover.

-

Remove air duct - C - and (depending on vehicle model) mount for bumper cover - A -.

-

Unplug connector - A - from A/C Pressure/temperature Sensor G395 - B -.

-

Remove A/C Pressure/temperature Sensor G395 - B - (housing color "Grey"), tightening torque: 8 Nm.

NOTE:  A/C Pressure/temperature Sensor G395 with black housing may also be installed at the start of production. Attention is therefore to be
paid to part number on component (risk of interchange with High Pressure Sensor G65) Parts List.

-

Replace O-ring - C - (assignment Parts List).

A/C Pressure/temperature Sensor G395, pin assignments

Contact 1: Ground (GND)

Contact 2: Signal output (via air conditioner data bus system "Local Interconnect Network (LIN-Bus)" to control and display unit, Climatronic Control
Module J255)