Variable Valve Timing Actuator: All Technical Service Bulletins
Engine - MIL ON/DTC's P0014/P0024/P0366/P0346

15 06 04 

September 13, 2006

2012630

Condition

MIL on and one or more of the DTC's are stored as shown.

Supersedes Technical Bulletin Group 15 number 06-02 dated August 4, 2006 due to updated information. 

Affected Vehicles

Technical Background

The condition can be caused by one or more jammed Camshaft Adjustment Solenoid Valve(s) (N205 / N208 / N318 / N319). This may be due to
contamination (e.g. debris) of the Hydraulic Mechanism of the Solenoid Valve(s).

Production Solution

Not applicable.