Using a Multimeter , check the Leak Detection Pump (LDP) (V144) for resistance as follows:
If the specifications are not obtained:
-
Replace the Leak Detection Pump (LDP) (-V144-).
If the specified values are obtained:
Checking voltage supply
‹› The voltage for the Leak Detection Pump (LDP) (-V144-) is supplied through the the Engine Control Module (ECM) (J623).
-
Using a Multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical harness connector terminal 3 for voltage.
-
Operate the starter briefly.
Specified value: battery voltage.
-
Switch the ignition off.
-
Using a Multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical harness connector terminal 3 to the Engine Control Module (ECM)