Using a Multimeter , check the Leak Detection Pump (LDP) (V144) for resistance as follows: 

If the specifications are not obtained:

-

Replace the Leak Detection Pump (LDP) (-V144-).

If the specified values are obtained:

Checking voltage supply

‹› The voltage for the Leak Detection Pump (LDP) (-V144-) is supplied through the the Engine Control Module (ECM) (J623).

-

Using a Multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical harness connector terminal 3 for voltage.

-

Operate the starter briefly.

Specified value: battery voltage.

-

Switch the ignition off.

-

Using a Multimeter, check the Leak Detection Pump (LDP) (-V144-) electrical harness connector terminal 3 to the Engine Control Module (ECM)