audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Keyless Start Control Module > < How to Find Wiring Diagrams|Page 1694
Page 2
background image

Installing

When installing, always heed the following sequence, otherwise proper function of Energy Management Control Module J644 cannot be guaranteed.

1. Install ground (GND) wire 1 to battery on Energy Management Control Module J644
2. Screw Energy Management Control Module J644 item 4 on to body, tighten ground (GND) pin 2 and cap nut 5 to do so.
3. Connect ground (GND) wire to battery.
4. Connect electrical harness connector 3 to Energy Management Control Module J644
5. Perform necessary steps after connecting battery.

If Energy Management Control Module J644 was replaced, it must be coded.

Tightening torques

Keyless Start Control Module > < How to Find Wiring Diagrams|Page 1694