Pull vacuum hose -arrow- off fuel pressure regulator.

NOTE:  If fuel flows out at the vacuum connection on the fuel pressure regulator during the following pressure test, install a new fuel pressure regulator.

The fuel pressure must increase to approx. 4.0 bar positive pressure.

If specification is not obtained:

-

Install new pressure regulator as a trial measure and repeat the pressure test.
If fuel pressure still does not match specification, check fuel pump and supply line for damage (e.g. pinching) and replace if necessary.

If specification is obtained:

-

Reconnect vacuum hose.
Switch ignition off.
Observe pressure drop on pressure gauge to check leakage and residual pressure.

After 10 minutes the pressure should still be at least 3 bar.

If holding pressure drops below 3.0 bar:

-

Start engine and run at idle speed.

Switch ignition off after pressure has built up. At the same time close cut-off valve on VAG1318 pressure gauge (valve handle at 90 ° to direction
of flow).

-

Observe pressure drop on gauge.

If the pressure drops again, the following malfunctions are possible:

-

Connections on pressure gauge downstream of cut-off valve leaking

-

Fuel pressure regulator faulty

-

Fuel injectors leaking