A6 Quattro Sedan V8-4.2L (ART) (2000)
-
Connect multimeter (voltage range) to following socket on connector:
4-pin connector on
Specification
wiring harness, socket
1 + Ground (GND)
Battery voltage
-
Operate starter.
Specification: approx. battery voltage
If the specification is not obtained:
-
Check continuity of wiring from socket 1 to fuel pump relay via fuse. Correct open circuit if necessary.
If the specification is obtained:
-
Check output stage, See: Power Output Stages For Ignition Coils, Checking