audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Customer Interest for Power Distribution Module:|971015|Page 1226 > < Customer Interest for Power Distribution Module:|971015
Page 2
background image

b. Verify that no pins are bent or deformed.

c. Verify proper crimping as described and illustrated in Figure 1.

^

Pin/terminal must be crimped onto the wire (Figure 1, A).

^

Pin/terminal must be crimped onto the wire sheathing (Figure 1, B).

2. Mechanically check the contacts on the control module and connector.

Test the individual terminals by using the standard 0.63 mm male pin (see Figure 1 and Parts Table) to verify proper contact. Make sure that the test
pin is not twisted and is inserted correctly into the female terminal. The contact must be tight, but it must still allow the pin to slide into the terminal of
the control module connector.

Only use the 0.63 mm male pins because the female terminals are designed for these pins, which are the only terminals found in the connectors for the
above-mentioned control modules.

3. If the pin/terminal is deformed, improperly crimped or does not contact correctly, the contact must be replaced with the VAS 1978A repair kit or
ordered in sets.

WARRANTY

This TSB is informational only and not applicable to any Audi warranty.

REQUIRED PARTS AND TOOLS

ADDITIONAL INFORMATION

All parts and service references provided in this TSB are subject to change and/or removal. Always check with your Parts Department and service

Customer Interest for Power Distribution Module:|971015|Page 1226 > < Customer Interest for Power Distribution Module:|971015