audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Discharge Air Temperature Sensor / Switch, HVAC > < Fresh Air Blower Control Module|Page 15561
Page 1
background image

A/C Coupler O-ring: Service and Repair

O-rings For Refrigerant Circuit 

-

O-rings are only ever to be used once and then replaced. 

-

Moisten O-rings with refrigerant oil before installing. 

-

Pay attention to correct positioning of O-rings on pipe or in groove. 

-

Ensure absolute cleanliness when working (even the slightest contamination, e.g. a single hair, could cause leakage). 

NOTE: 
-

Only O-rings which are resistant to refrigerant R134a and the corresponding refrigerant oil may be installed. Such O-rings are color coded to
prevent mix-ups (currently "red", "lilac" or "violet" ): Parts List

-

Dimensions - a - and - b - differ depending on component location of O-ring: Parts List 

-

In addition to the colored O-rings, black O-rings are also used at the factory for certain connections.

Discharge Air Temperature Sensor / Switch, HVAC > < Fresh Air Blower Control Module|Page 15561