Specified value: 0.400 to 0.500 Volts

-

Switch the ignition off.

If the specified value was obtained:

-

Replace the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131). 

If the specified value was not obtained:

Checking wiring

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Removing and Installing ] See: Engine
Control Module/Service and Repair/Engine Control Module.

-

Using a Multimeter, check the Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) electrical harness connector
terminals to the Motronic Engine Control Module (ECM) (J623) electrical harness connector T94a terminals for an open circuit.