audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor and Sensor Regulation before Catalytic Converter, Checking|Page 7636 > < Heated Oxygen Sensor and Sensor Regulation before Catalytic Converter, Checking|Page 7634
Page 6
background image

-

Disconnect the Heated Oxygen Sensor (HO2S) 2 (G108) electrical harness connector - 1 -.

Checking internal resistance

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) 2 (G108) terminals 3 to 4 for resistance. 

Specified value: 2.5 to 10.0 ohms (at approx. 20° C)

If the specification was not obtained:

-

Replace Heated Oxygen Sensor (HO2S) 2 (G108).