audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Knock Sensor|Locations|Page 7963 > < Knock Sensor|Locations|Page 7961
Page 9
background image

and Procedures/Preliminary Check.

Start diagnosis

-

Remove the intake manifold.

-

Disconnect the brown Knock Sensor 4 (G199) electrical harness connector- 1 -.

Checking internal resistance

-

Using a Multimeter, check the Knock Sensor 4 (G199) terminals 1 to 2 for an internal short. 

Specified value: infinite (Infinity).

If the specified value was not obtained:

-

Replace Knock Sensor 4 (G199). 

If the specified value was obtained:

Checking wiring

If the manufacturers test box is being used. Perform the following step.

-

Install the test box. 

If the manufacturers test box is not being used. Perform the following step.

-

Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Removing and Installing ] See: Engine

Knock Sensor|Locations|Page 7963 > < Knock Sensor|Locations|Page 7961