Check voltage supply for Fuel Pump (FP) (from Fuel Pump (FP) Control Module J538)

-

Remove rear seat bench.

-

Unbolt cover for right locking flange - arrows -.

-

For voltage testing, connect the hand multimeter V.A.G 1526C with measuring probes and connector adapters from the connector test set V.A.G
1594C between clamp -1 -and - 5 -, as shown in the illustration. The electrical connection remains connected.

NOTE:  Connector sockets are numbered respectively on the rear side of the connector.

-

Start engine. 
-

Specified value at start and in idle: 4 to 5 V.

-

Depress accelerator pedal completely and then release it (brief throttle burst).
-

Specified value: The voltage value must first rise slightly, then fall and then rise again to the value previously read.

If the reading does not result as described:

-

Check voltage supply and activation of Fuel Pump (FP) Control Module J538.

Check voltage supply for Fuel Pump (FP) Control Module J538

-

Remove Fuel Pump (FP) Control Module J538.

-

Disconnect electrical harness connector - arrow - on Fuel Pump (FP) Control Module J538.

Fuel Pump Control Unit|Locations|Page 8792 > < Fuel Pump Control Unit|Locations|Page 8790