A6 Quattro Sedan V8-4.2L (BVJ) (2007)
-
Crank the engine.
-
Using a multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminals
3 to 4 for voltage.
Specified value: 0.400 to 0.500 Volts
-
Switch the ignition off.
If the specified value was obtained:
-
Replace the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130).
If the specified value was not obtained:
Checking wiring
If the manufacturers test box is being used. Perform the following step.
-
Install the test box.
If the manufacturers test box is not being used. Perform the following step.
-
Remove the Motronic Engine Control Module (ECM) (J623). Refer to => [ Engine Control Module, Removing and Installing ] See: Powertrain
Management/Computers and Control Systems/Engine Control Module/Service and Repair/Engine Control Module.
-
Using a Multimeter, check the Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) electrical harness connector terminals
to the Motronic Engine Control Module (ECM) (J623) electrical harness connector T94a terminals for an open circuit.