Instrument Panel Voltage Regulator: Testing and Inspection

Voltage stabilizer

-

Leave battery ground strap connected.

-

Leave all instrument cluster connectors attached.

-

Set digital multimeter (Fluke 83 or equivalent) to volt range.

-

Connect red multimeter test lead to terminal -1- (+) and black multimeter test lead to terminal -2- (ground).

-

Switch ignition ON.

-

Must be approx. battery voltage

If NOT:

-

Check wiring for open circuit according to wiring diagram, repair as necessary.

-

Connect red multimeter test lead to terminal -3- and black multimeter test lead to terminal -2- (ground).

-

Switch ignition ON.

-

Must be 9.75 - 10.25 volts

If NOT:

-

Replace printed circuit.