audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Relays and Modules - Fuel Delivery and Air Induction > < LED Test Light|Page 4878
Page 2
background image

Systems/Testing and Inspection

-

Check whether rotary slide valve runs properly from stop to stop.

If there are signs of scoring that impair free movement, or if the rotary slide does not move freely (sticks, runs slowly or does not run up to
both stops):
-

Replace idle air control valve

If there is no valve activation during output DTM:
-

Check IAC valve activation.

CHECKING IDLE AIR CONTROL VALVE ACTIVATION 

^

Electrical check OK.

Idle Air Control Valve Terminal Identification

-

Push back boot from harness connector (stays connected).

-

Use On-Board Diagnostics, Output Diagnostic Test Mode (DTM) to activate idle air control valve. See: Computers and Control
Systems/Testing and Inspection

-

Connect US 1115 LED tester or equivalent between harness connector terminal 1 and Ground (GND).
^

LED must blink

-

Connect LED tester between harness connector terminal 2 and battery positive (B+).
^

LED must light up

If specified results are not obtained:
-

Check for open circuit or short circuit between IAC valve harness connector and ECM harness connector.

-

Eliminate wiring break or short circuit as necessary.

If wiring is OK and activation fails:
-

Replace ECM.

If activation and wiring is OK and there is still no valve reaction:
-

Replace mechanically seized valve.

Relays and Modules - Fuel Delivery and Air Induction > < LED Test Light|Page 4878