audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Camshaft Adjustment, Checking|Page 3741 > < Camshaft Adjustment, Checking|Page 3739
Page 2
background image

Display on VAS5051:
A - Actuator test is waiting Advancing by switching required
5- Bank 1, camshaft adjustment => -N205
-

Click on (arrow) button

Display on VAS5051:
A - Actuator test is running Advancing by switching allowed
This valve is activated for approximately 1 minute (clicks), unless , (arrow) button is pressed first to switch to the next actuator.
-

Click on (arrow) button

Display on VAS5051:
A - Actuator test is waiting Advancing by switching required
6- Bank 2, camshaft adjustment => - N208
-

Click on (arrow) button

Display on VAS5061:
A - Actuator test is running Advancing by switching allowed
This valve is activated for approximately 1 minute (clicks), unless (arrow) button is pressed first to switch to the next actuator.
-

End function "03- output Diagnostic Test Mode (DTM)" by pressing button.

If one of the valves is not being activated (does not click).
-

Switch ignition off.

-

Perform an electrical test for the valves for camshaft adjustment.

Valves for camshaft adjustment (exhaust), activating
-

Initiate output Diagnostic Test Mode (DTM) and activate valve for camshaft adjustment (exhaust) bank 1:

Camshaft Adjustment, Checking|Page 3741 > < Camshaft Adjustment, Checking|Page 3739