background image

Valve for camshaft adjustment (intake):
-

Connect multimeter between terminals 1 and 2 for resistance measurement.
^

Specification: 7.4 to 8.2 Ohms

Valve for camshaft adjustment (exhaust):
-

Connect multimeter between terminal 2 and 3 for resistance measurement.
^

Specification: 12.8 to 14.2 Ohms

All:
If specified value is not obtained:
-

Replace valve.

If specified value is obtained:

Checking voltage supply
Test requirement:
Fuse for valves for camshaft adjustment OK.
Refer to, Electrical Wiring Diagrams, Troubleshooting & Component Locations

-

Connect VAG1 527B voltage tester as follows:

-

Switch ignition on.
^

LED must light up.

If LED does not light up: