A6 Quattro Wagon V6-3.0L (AVK) (2002)
-
Select function "35" in button field -2- For "Adaptation channel 35" and press Q button to confirm input.
Display on VAS5051:
1
-
Channel 35 read and test
2
-
No indication
3
-
Keypad - only direct input via the keypad is possible
4
-
The sliding bar is positioned on the current adaptation value, e.g. 0
NOTE:
-
The adaptation value of 0 corresponds to the value set at the factory For the oil pressure warning if the oil pressure drops below 1.2 bar at 1500
RPM.
-
The adaptation can be performed in four steps (0-1000).
-
The adaptation value of "250" changes the engine speed threshold to 1750 RPM.
-
Only direct input via the keypad is possible!
-
If the value "0" was changed due to a customer complaint, the changed value must be transferred to the new instrument cluster during replacement.
-
Change adaptation value via direct input See "B - Change adaptation value via direct input".
-
Enter 5-digit adaptation value. Insert zeros in front.
Example:
Desired input value: + 250 RPM
Keypad input: 00250