A6 Quattro Wagon V6-3.0L (AVK) (2002)
Air Duct: Service and Repair
Air Duct With Intake Housing, Disassembling And Assembling
-
Air conditioner unit removing.
-
Disassembling and assembling air conditioner unit.
NOTE:
-
Starting September 1998, there was a running change in production from the version "1" air conditioner to the version "2" air conditioner.
-
From model year 2002 air conditioner version "3" is installed
-
From version "3" a second positioning motor has been installed at the intake duct.
-
From version "3", the air recirculating/fresh air flap is actuated by Recirculation Flap Motor -V113- and no longer by the Air Flow Flap Motor
-V71-.
Air duct and intake housing (vehicles from model year 2002)
1
-
Bolt
2
-
Control module for fresh air blower -J126-
3
-
Bolt
4
-
Fresh Air Blower -V2-
-
The blower wheel for the fresh air blower installed in version "2" air conditioning unit is approx. 10 mm shorter than the one in version