A6 Quattro Wagon V6-3.0L (AVK) (2002)
-
Loosen mounting parts -1 to 4- and remove noise insulation.
-
Disconnect pressure hose -1- at Secondary Air Injection (AIR) Pump Motor and blow into it with light pressure (do not use pressurized air).
-
Both combination valves must be closed, it must not be possible to blow through hose
-
Operate hand vacuum pump.
-
The relevant combination valve must open, it must not be possible to blow through
If the relevant combination valve does not open:
-
Replace combination valve.