Adaption (Function 10)|Page 6646 > < Adaption (Function 10)|Page 6644
Page 6
background image

-

Select function "30" in button field -2- For "Adaptation channel 30" and press Q button to confirm input.

Display on VAS5051:

1

-

Channel 30 read and test

2

-

Tank sensor

3

-

Keypad - only direct input via the keypad is possible

4

-

The sliding bar is positioned on the current adaptation value, e.g. 128

NOTE:

-

"128" is the adaptation value For the standard resistance range For the fuel gauge sender as set by the factory.

-

The resistance value For the fuel gauge sender resistance range can be adjusted by = 8 Ohm to give an adaptation value between 120 and 136.

-

Only direct input via the keypad is possible!

-

If the value "128" was changed due to a customer complaint, the changed value must be transferred when replacing instrument cluster.

-

Change adaptation value via direct input See"B - Change adaptation value via direct input".

-

Enter 5-digit adaptation value. Insert zeros in front.

Example:
Desired input value: 132
Keypad input: 00132

-

Then observe impact on display.

Display on VAS5051 after performed adaptation:

Adaption (Function 10)|Page 6646 > < Adaption (Function 10)|Page 6644