A6 Quattro Wagon V6-3.0L (AVK) (2002)
If the malfunction remains in the same cylinder:
-
Replace ignition coil from faulty cylinder with one from another cylinder.
If the malfunction moves with the ignition coil:
-
Replace ignition coil.
Check Ground connection
-
Remove cover -1- on left in engine compartment.
-
Unbolt coolant expansion tank (arrow).
-
Disconnect electrical wiring to engine coolant level (ECL) warning switch -F66- on bottom of expansion tank.
-
Lay coolant expansion tank with connected coolant hoses -1 to 3- aside.
-
Remove cover -1- on right in engine compartment.