audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Procedures|Page 16410 > < Procedures
Page 2
background image

cleaning. 

-

Clean the installation compartment for dust and pollen filter of heating and A/C unit of leaves, dust and other contaminants using a standard
vacuum cleaner, suction nozzle with bush VAS 6288 (and hose attachment).

-

Close again the opening, over which the dust and pollen filter was removed, on heating and A/C unit.

-

Start engine. 

-

Set operating mode "recirculated air mode" on Climatronic Control Module J255 and switch off compressor "Econ mode". 

-

Open instrument panel vents and set the lowest possible temperature for drivers and front passengers sides (e.g. temperature preselect "Lo" ) on
Climatronic Control Module J255. 

-

Close vehicle windows and sunroof. 

-

Set Climatronic Control Module J255 to lowest air blower speed and select "instrument panel vents" for the air outlet direction. 

Cleaning

-

Shake the bottle of cleaning fluid VAS 6189/1 and pour into ultrasonic HVAC cleaning system VAS 6189 ,note the ultrasonic HVAC cleaning
system VAS 6189 operating instructions when doing this. 

-

Place the ultrasonic HVAC cleaning system VAS 6189 in the front passengers footwell. 

-

Start up the ultrasonic HVAC cleaning system VAS 6189 (according to operating instructions) and route the outlet hose belonging to it so that the
vapor escaping via the recirculated air opening of the heating and A/C unit (beneath instrument panel) is drawn in by the Fresh Air Blower V2. 

-

Close vehicle doors. 

NOTE:  Cleaning procedure lasts approx. 15 to 20 minutes, it is complete when vapor no longer escapes from outlet hose. 

Final procedures 

-

Switch off the ultrasonic HVAC cleaning system VAS 6189. 

-

Open vehicle doors and ventilate vehicle for a minimum of 10 minutes.

-

Remove ultrasonic HVAC cleaning system VAS 6189 from vehicle and clean it according to the operating instructions. 

-

Switch ignition off. 

-

Install dust and pollen filter.

Procedures|Page 16410 > < Procedures