audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heated Oxygen Sensor after Catalytic Converter, Checking|Page 8058 > < Heated Oxygen Sensor after Catalytic Converter, Checking|Page 8056
Page 3
background image

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) 2 terminals 1 to 2 for resistance.

Specification: 2.5 to 10 ohms (at room temperature).

If the specification is not obtained:

-

Replace the Heated Oxygen Sensor (HO2S) (-G130-) (bank 1, sensor 2) or Heated Oxygen Sensor (HO2S) (-G131-) (bank 2, sensor 2) behind
Three Way Catalytic Converter (TWC).

If the specified value is obtained:

Checking voltage supply

-

Connect a multimeter between Heated Oxygen Sensor (HO2S) 2 (G108)terminals 1 and 3 for voltage measurement.

-

Operate the starter briefly.

Specified value: Battery voltage.

-

Switch the ignition off.

If no voltage is present:

-

Using a multimeter, check the Heated Oxygen Sensor (HO2S) electrical harness connector terminal 1 to engine ground (GND) for voltage.

Heated Oxygen Sensor after Catalytic Converter, Checking|Page 8058 > < Heated Oxygen Sensor after Catalytic Converter, Checking|Page 8056