A6 Quattro Wagon V6-3.2L (BKH) (2006)
-
Repair open circuit in wiring according to wiring diagram.
Checking output wiring
-
Connect (V.A.G 1527B) as follows:
-
Initiate output Diagnostic Test Mode (DTM).
Display on (VAS 5051B):
A Output diagnostic test mode waiting, Advancing by switching required.
1
Evaporative emission (EVAP) canister purge regulator valve 1.
-
Press the -> button repeatedly, until leak detection pump (LDP) is activated.
‹› LED must blink.
If LED does not blink:
-
End function "005 - output Diagnostic Test Mode (DTM)" by pressing <- button.
-
Select "022 - End output" function in selection.
-
Switch off ignition.