Using multimeter with auxiliary wires from VAG 1594, measure resistance across terminals on valve.
Specified value: 10-18 ohms

If resistance is not as specified:

-

Replace solenoid valve.

Checking voltage supply of valves for camshaft adjustment

-

Disconnect harness connector from valve.

-

Connect LED tester VAG 1527 between engine ground and terminal 1 of connector (B+).

-

Crank starter for several seconds (engine can start).
LED in voltage tester must light up.

If LED does not light up, conduct the following tests:

-

Check fuse for valves for camshaft adjustment.

-

Check wiring from terminal 1 on 2-pin connector to fuse for continuity per wiring diagram.

-

Check fuel pump relay and signal to relay. See: Powertrain Management/Fuel Delivery and Air Induction/Fuel Pump/Fuel Pump Relay/Testing
and Inspection 

Checking signal to valves for camshaft adjustment

-

Disconnect harness connector from valve.