background image

-

Display field -1- indicates request to input display group.

-

Display field -2- shows input keyboard.

-

Input via keyboard in display field 2 the desired display group umber "015" (See overview of selectable display groups). Refer to Scan Tool
Testing/Measuring Value Blocks (Function 08)" under "Heating and Air Conditioning", See: Testing and Inspection 

-

Confirm input using the -Q- button.

-

Check indications shown in display fields -1- and -2- 

NOTE:  Display field -1- shows the operating conditions of fresh air/recirculation flap and display field -2- indicates the condition of the air quality
sensor signal. Clarification of possible displays. Refer to Scan Tool Testing/Measuring Value Blocks (Function 08)/Display Group 015" under "Heating
and Air Conditioning", See: Testing and Inspection 

-

Specified value in display field -1-: 00 or 0
(no request for "air recirculation mode", climate control in fresh air mode)

or

-

Specified value in display field -1-: 60
("Partial air recirculation mode", the fresh air/recirculation flap is so positioned that approx. 1/3 air is sucked in from the passenger compartment)

-

Place spray head -A- of test bottle over air inlet of sensor for air quality -B-.

-

Activate spray head -C- of test bottle for 1 second.

NOTE:

-

The content of the test bottle consists of pure oxygen with a specified amount of nitrogen oxide.

-

If the sensor comes in contact with cigarette smoke or gas from a lighter it will react.

-

Read value indicated in display field -1-.
-

Specification: 10