Coolant Temperature Sensor/Switch (For Computer): Customer Interest
Engine - Cranks But Won't Start

Group: 15 
Number: 01-02
Date: May 24, 2001

Subject:
Engine Cranks But Will Not Start

Model(s):
A4, A6 with 2.8L 5V

1998-->2000

Supersedes T.B. Group 15 Number 01-01 dated Feb. 13, 2001 due to corrected VIN.

Condition

Engine cranks but will not start.

Service

After vehicle sits for a minimum of several hours (preferably overnight), do the following:

-

Be sure battery is fully charged.

-

Be sure there is a sufficient amount of fuel in the tank.

-

Connect VAS 5051 scan tool.

-

Select vehicle system "01 - Engine electronics".

-

Select diagnosis function "02-Interrogate fault memory" to check for stored DTC's. Select "Print" and "Save Result". Do not print screens! (Select
"Yes" at prompt "Erase old log?", if applicable).

Note:

In most cases no DTC's will be found, and the readiness code will be set.

-

Take corrective action for any stored DTC's according to DTC table in the OBD II Fuel Injection & Ignition section of the 2.8 Liter V6 5V Repair
Manual; re-set readiness code.

-

Select back arrow.