A6 Sedan V6-2.8L (ATQ) (2000)
Tool Testing/Scan Tool Connecting And Initial Checks", See: Testing and Inspection
Engine must run at idle for this.
When indicated on display:
Rapid data transfer
HELP
Select function XX
-
Press buttons -0- and -4- to select "Initiate basic setting" and press -Q- button to confirm input.
NOTE: During basic setting, the Evaporative Emission (EVAP) canister purge regulator valve (EVAP valve -N80-) is closed and the A/C compressor is
switched off
When indicated on display:
Basic Setting
Q
Input display group number XXX
-
Press buttons -0-, -0- and -2- to select "display group number 002" and press -Q- button to confirm input.
When indicated on display:
System in Basic Setting 2
->
1
2
3
4
-
Check specified values for load detection in display fields 3 and 4.
If specified values are obtained:
-
Press -> button.
Indicated on display (function selection):
Rapid data transfer
HELP
Select function XX
Evaluation display group 002