audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Fuel Pressure Regulator|Testing and Inspection|Page 11342 > < Fuel Pressure Regulator|Testing and Inspection|Page 11340
Page 3
background image

-

Wait until pressure has dropped, and then switch off ignition. Simultaneously close shut- off valve of VAG1318 pressure gauge (lever
perpendicular to direction of flow -arrow-).

The following malfunction are possible if the pressure does not drop:

-

There is a leak in the threaded connection between the pressure gauge and the fuel supply line

-

There is a leak at the supply line at fuel tank.

-

There is a leak in the check valve in the Fuel Pump (FP).

NOTE:  Pressure gauge displays the pressure behind the stopcock "intake manifold side" after the stopcock is closed (in direction of fuel injector, fuel
pressure regulator). If the pressure drops in front of the stopcock (in direction of fuel tank), the device cannot detect it. For this reason, the center of this
page states "If the pressure does not drop..".

The following malfunctions are possible if the pressure drops again:

-

Fuel pressure regulator faulty

-

Fuel injectors not properly sealed

-

Threaded connections of pressure gauge behind stopcock is not properly sealed.

NOTE:  Close stopcock for removing the pressure gauge, loosen threaded connection at VAG1318/15 adapter and let excess fuel escape into catch
reservoir by opening stopcock.