Connect one terminal of solenoid valve to engine Ground (GND) using an adapter cable and an alligator clip from VAG1594A connector test kit.

-

Connect the second terminal of solenoid valve to B+ using VAG1348/3A remote control, VAG1348/3-2 adapter cable and assisting cable.

-

Operate VAG1348/3A remote control for approx. 2 to 3 minutes. Vacuum diaphragm must remain activated during this time.

If the vacuum diaphragm moves back, check vacuum reservoir as follows:

-

Disconnect vacuum hoses from vacuum reservoir for intake manifold change-over.

-

Connect VAG1390 hand vacuum pump to vacuum reservoir.

-

Operate hand vacuum pump and observe change-over procedure.

-

Check vacuum reservoir for proper seal. (Vacuum reservoir must not return to rest position, as long as the hand vacuum pump is not vented.)

-

Replace vacuum reservoir if necessary.

-

If the vacuum diaphragm does not activate, check Intake Manifold Change-Over Valve -N156- for continuity as follows:

-

Connect one terminal of Intake Manifold Change-Over Valve -N156- to engine Ground (GND) using an adapter cable and an alligator clip from
VAG1594A connector test kit.

-

Connect the second terminal of Intake Manifold Change-Over Valve -N156- to B+ using VAG1348/3A remote control, VAG1348/3-2 adapter
cable and assisting cable.

-

Operate VAG1348/3A remote control.

-

Check valve for throughput (disconnect vacuum hose and blow through).

-

If necessary, replace intake manifold change-over valve.

-

Check vacuum system for leaks if no malfunctions were detected for all previous tests.