audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Recirculation Door Motor|Page 16060 > < Recirculation Door Motor|Page 16058
Page 3
background image

‹› If connecting element - A - cannot be inserted into the control motor without pretension, the shaft may be incorrectly positioned. 

-

Install actuator - B -.

-

Attach the connecting element - D - to the shaft of the control motor, making sure both connecting elements - D - and -  E - are positioned
correctly in relation to each other.

‹› Reach into the vent if necessary and place the door - F - in the correct position.

‹› Check connecting element for proper seating, it must engage in motor shaft and there must not be any clearance between actuator shaft and

connecting element.

‹› If there are doubts as to whether the connecting elements -  D - and - E - are positioned correctly in relation to each other, connect the control

motor terminals "5" and " 6" to a 12 V battery via a 5A fuse using an adapter cable => [ Preparing Adapter Cables for Control Motor Actuation ] 
See: Description and Operation/Preparing Adapter Cables for Control Motor Actuation or an auxiliary cable from the Connector Test Set (V.A.G
1594/C). Let the control motor run until it has reached an end position (the direction of rotation can be changed by switching Plus and Minus) and
watch both connecting elements while it runs.

-

Install the removed components again in reverse order.

-

Check the DTC memory for the Climatronic Control Module (J255) A/C control head and erase any faults displayed if necessary.

-

Perform a basic setting and output diagnostic test mode on the A/C system.

Recirculation Door Motor|Page 16060 > < Recirculation Door Motor|Page 16058