Attach connecting element - A - on to the shaft of control motor - B -.

‹› Only install the connecting element - A - in the position where it engages without being forced in. If pretension is needed to insert the connecting

element, check the motor shaft - B -. It can be rotated 180°.

‹› Check connecting element for proper seating, it must engage in motor shaft and there must not be any clearance between actuator shaft and

connecting element.

‹› If motor shaft - B - is not in the position depicted (the connecting piece can only be attached in this position), connect terminals " 5" and "6" of the

control motor via a 5A fuse to a 12 V battery e.g. using adapter lead => [ Preparing Adapter Cables for Control Motor Actuation ] See:
Description and Operation/Preparing Adapter Cables for Control Motor Actuation (or an adapter lead from the Connector Test Kit (V.A.G
1594/C)). Rotate the control motor for as long until the shaft is located in the position depicted (the connecting element can be connected without
pretension), the turning direction can be reversed by swapping Plus and Minus.

‹› The control motor shaft - B - does not have a stop, it rotates continuously when voltage is applied to terminals "5" and " 6". Therefore,if the

connecting element - A - is connected or cannot be connected, voltage should be applied only when the control motor has been removed in order
to bring shaft into the correct position.

‹› If connecting element - A - cannot be inserted into the control motor without pretension, the shaft may be incorrectly positioned. 

-

Install the control motor - B -, making sure both connecting elements - D - and - E - are positioned correctly in relation to each other.

‹› Reach into the vent if necessary and place the door - F - in the correct position.

‹› If there are doubts as to whether the connecting elements -  D - and - E - are positioned correctly in relation to each other, connect the control

motor terminals "5" and " 6" to a 12 V battery via a 5A fuse using an adapter cable => [ Preparing Adapter Cables for Control Motor Actuation ] 
See: Description and Operation/Preparing Adapter Cables for Control Motor Actuation or an auxiliary cable from the Connector Test Set (V.A.G
1594/C). Let the control motor run until it has reached an end position (the direction of rotation can be changed by switching Plus and Minus) and
watch both connecting elements while it runs.