A6 Sedan V6-3.2L (BKH) (2007)
-
Remove the bracket - A - for the coolant pipe - D -.
-
Remove the clamp - E -.
-
Place a container under the connector for the coolant pipe - D - at the heat exchanger.
-
Remove the coolant pipe - D - from the heat exchanger
-
Remove the coolant hoses that have already been marked (risk of transposition) from the connectors - B - and - C -.
-
Remove the grommet - A -.
-
Depending on the vehicle equipment, remove the electric control modules and corresponding holders preventing the removal of the evaporator
(e.g. the Front Information Display Control Head Control Module (J523)) => Communication 91 Removal and Installation
Removing
‹› Perform preparatory work for removing the evaporator.
-
Release the thermal insulation - A - from the refrigerant line connection flange at the evaporator - E - (to the left at the A/C unit).