A6 Sedan V6-3.2L (BKH) (2007)
-
Disconnect the electrical connector - arrow - at locking flange.
-
Connect a hand held remote control (jumper) using an adapter cable from the connector test set to contact 5.
-
Using insulating tape, tape over second contact of the remote control (jumper) to prevent a short circuit.
-
Route switch of the remote control (jumper) forward into the engine compartment.
-
Connect alligator clip to ground (GND) point in engine compartment.
-
Connect contact 1 to battery positive terminal (B+) using a self-made jumper cable. For safety reasons, install a 10 A fuse in the wiring.
-
Remove fuel filler cap from fuel filler tube.
-
Pull rear engine cover off - arrows -.
-
Pull resonator upward and unclip it.
CAUTION!
Fuel system is under pressure! Before opening system, place rags around the connection area. Then release pressure by carefully
loosening the connection.
-
Disconnect fuel line - arrow -.