A8 Quattro Sedan V8-4.2L (AKB) (2002)
Power Steering Pressure Control Valve: Testing and Inspection
Servotronic, Checking Voltage Supply
Servotronic, Checking Voltage Supply
^
Open electronics box in passenger side footwell.
^
Pull off Servotronic control module -J236-, position 12.
^
Switch ignition off.
^
Set digital multimeter (Fluke 83 or equivalent) to voltage measuring range, maximum 20 volts.
^
Take measurement at relay connector between contacts -6- and -8-.
Specified value: approximately 12 volts.
^
Check wiring if specified value is not attained.