audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Procedures|Page 6983 > < Procedures|Page 6981
Page 4
background image

-

Loosen impact area with hard metal awl but do not expand it or remove any glass fragments.

-

Remove any possible moisture with suction hooks while helping with hair dryer from inside. Stop repair if moisture cannot be removed.

-

Mount mirror - 1 - on inside and align so location of damage can be seen clearly.

-

Mount tool carrier - 2 - with injector - 3 - so injectors rubber seal lies directly over point of impact. Check by looking in mirror.

-

Completely remove threaded spindle - 2 - from injector - 1 - .

-

Fill injector - 1 - with 2 to 3 drops resin (this amount is resin is sufficient for any damage).

-

Return resin bottle to package immediately because resin is UV sensitive.

-

Wait until resin advances into rubber seal.

-

Tighten injector - 1 - by turning threaded spindle - 2 - . The correct pressure is achieved when the impact point turns clear from the center out.

NOTE:  The resin penetrates into the cracks very slowly and may not be visible right away.

-

Wait 10 minutes, then release injector to end of threads.

-

Hold injector tightly when loosening so that it does not slip.

-

Repeat procedure (at least 3 times) until all air is removed from damage location. You can recognize this by the fact that all of the cracks will no
longer be visible. Tightening the injector creates pressure up to 18 bar.

-

Note in mirror when the damage location is filled. Then end injection.

-

Then swing carrier with injector to side and check whether resin has flowed into all points of fracture.

-

Remove any possible trapped air with the suction hook placed on the repair location.

Procedures|Page 6983 > < Procedures|Page 6981