audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Blower Motor Relay > < How to Find Wiring Diagrams|Page 14967
Page 2
background image

-

Disconnect connector - C - from Fresh Air Blower Control Module (J126).

-

Remove the Fresh Air Blower (V2).

CAUTION!
Do not grasp fans of Fresh Air Blower. Force against fans or shifting balancing weights fastened to fans may cause imbalance and then
problems during operation.

Installing

Installation is carried out in the reverse order, when doing this note the following:

-

When installing, ensure wiring is routed correctly to connector -  C -.

-

Check the DTC memory for the Climatronic Control Module (J255) A/C control head and erase any faults displayed if necessary Vehicle
diagnosis, testing and information system VAS 5051 in the "Guided Fault Finding" function.

Blower Motor Relay > < How to Find Wiring Diagrams|Page 14967