audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Procedures|Page 15815 > < Initial Inspection and Diagnostic Overview|Page 15812
Page 1
background image

Climate Control Exhaust Gas Sensor: Procedures

Air Quality Sensor G238, Removing And Installing

NOTE:

-

Air Quality Sensor G238 is a highly sensitive electronic component which could be destroyed by direct exposure to solvents, fuels and certain
chemical compounds (contamination can ingress by way of area - A - for example).

-

For this reason, never install sensors which have been exposed to unsuitable environments.

-

Following removal, do not set down sensor in areas where it could come into contact with solvents, fuels or certain chemical compounds (liquids
or vapors).

-

There are various housings for the Air Quality Sensor G238, but the mode of operation is always identical

Removing and installing

-

Remove plenum chamber cover on right.

-

Unplug connector - A - from sensor.

-

Turn sensor through 90° and lift sensor - B - out of mount.

Contact assignment in connector - A -

1. Positive (terminal "15")
2. Negative (terminal "31")
3. Signal wire to Climatronic Control Module J255; measured value is indicated in measured value block of Climatronic Control Module J255

(display group "022"); square-wave signal cannot be evaluated using workshop equipment

Procedures|Page 15815 > < Initial Inspection and Diagnostic Overview|Page 15812