Climate Control Exhaust Gas Sensor: Component Tests and General Diagnostics

Air Quality Sensor, Checking

-

With the ignition switched off, connect the Vehicle Diagnosis, Testing And Information System (VAS 5051 A) with the Diagnostic Cable - 3
Meter (VAS 5051/5A) to the 16-pin data link connector on the vehicle diagnosis, testing and information system VAS 5051 in the "Guided Fault
Finding" function.

-

Start the engine.

-

Check the DTC memory of the Climatronic Control Module (J255) front A/C control head vehicle diagnosis, testing and information system VAS
5051 in the "Guided Fault Finding" function.

-

Set operating mode "Auto" on front A/C control head Climatronic Control Module (J255).

-

Switch on the "automatic air recirculation" function via the front A/C control head Climatronic Control Module (J255) (function is displayed on
screen of Multi Media Interface). 

-

Wait 30 seconds (warm up time for Air Quality Sensor (G238)).

-

Select "Read measuring value block" on the Vehicle Diagnosis, Testing And Information System (VAS 5051 A). vehicle diagnosis, testing and
information system VAS 5051 in the "Guided Fault Finding" function

-

Read the displays with the signal from the Air Quality Sensor (G238) and to the position of the recirculation flap vehicle diagnosis, testing and
information system VAS 5051 in the "Guided Fault Finding" function.

‹› The A/C system operating condition (position of the recirculating/fresh air flap) and the condition of the signal from the Air Quality Sensor (G238)

are displayed. Explanation of the possible displays vehicle diagnosis, testing and information system VAS 5051 in the "Guided Fault Finding"
function.

‹› Specification: no request for "Recirculating air mode" present, (air conditioning in fresh air mode)

Or

‹› Specification: no request for "automatic recirculation mode" present, request for "partial recirculation mode" present (fresh air/recirculating door

in the center position)

-

Remove the Air Quality Sensor (G238) from the mount. Refer to => [ Air Quality Sensor ] See: Service and Repair/Removal and Replacement.

-

Allow a little bit of gas from the lighter flow past -  - from the top area - A - of the Air Quality Sensor (G238)

‹› If the Air Quality Sensor (G238) comes in contact with cigarette smoke or with gas from an ignitor, it will react since ignitor gas is heavier than

air; remove the Air Quality Sensor (G238).

‹› There are different versions of the Air Quality Sensor (G238), each with different functions. Make sure the allocation is correct. .

Initial Inspection and Diagnostic Overview|Page 15811 > < Initial Inspection and Diagnostic Overview