Operate starter briefly.

Specified value: approx. battery voltage

‹› Ground (GND) from the ECM is present at terminal 3 of connector.

If specified value is not obtained, check wire connections.

-

Connect multimeter to terminal 3 and terminal 4 of connector for voltage measurement.

-

Switch ignition on.

Specified value: approx. 5 Volts.

If specified value is not obtained, check wire connections.

Wire Connections, Checking

‹› Signal wire is also checked during wire test.

-

Connect test box (VAG1598/31) to wiring harness of Engine Control Module (ECM), refer to Repair Manual.