Heated Oxygen Sensor (HO2S) 2 (G108) before catalytic converter bank 2, with Oxygen Sensor (O2S) 2 Heater (Z28)

-

Operate starter briefly. (Do not let engine run longer than 2 minutes, because of malfunction entry)

Specified value: approx. battery voltage

-

Switch ignition off.

If specified value is not obtained, check wire connection.

-

Connect test box (VAG1598/31) to wiring harness of Engine Control Module (ECM), 

-

Check the following wire connections for open circuit.

Heated Oxygen Sensor (HO2S) (G39) before catalytic converter bank 1, with Oxygen Sensor (O2S) Heater (Z19)

Heated Oxygen Sensor (HO2S) 2 (G108) before catalytic converter bank 2, with Oxygen Sensor (O2S) 2 Heater (Z28)

-

Repair open circuit in wiring or short circuit if necessary. 

-

If wire connection is OK but there is no Ground (GND) activation present for oxygen sensor heater, replace Engine Control Module (ECM), refer
to Repair Manual and generate readiness code again => [ Readiness Code, Generating ] See: Testing and Inspection/Monitors, Trips, Drive Cycles
and Readiness Codes. 