audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 7573 > < Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 7571
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensors After Catalytic Converter, Checking Signal Wire and Activation

Oxygen Sensors after Catalytic Converter, Checking Signal Wire and Activation

Component location => [ Heater for Oxygen Sensor before Catalytic Converter, Checking ].

‹› Oxygen sensor signals are monitored via On Board Diagnostic (OBD). 

-

Check DTC memory. If an oxygen sensor malfunction is displayed. 

-

Disconnect respective harness connector for oxygen sensor (connector strip bolted to underside of transmission).

2

4-pin harness connector for Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) and Oxygen Sensor (O2S) Heater 1
(Z29) behind catalytic converter, bank 1

3

4-pin harness connector for Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) and Oxygen Sensor (O2S) Heater 2
(Z30) behind catalytic converter, bank 2

-

Perform voltage measurement between terminals 3 and 4 of connector at wiring harness using portable multimeter (VAG1526) (measurement
range 2 V).

-

Switch ignition on.

Specified value: 450 ± 50 mV behind catalytic converter.

-

Switch ignition off.

If specified value is not obtained, check wire connections.

Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 7573 > < Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 7571