A8 Quattro Sedan V8-4.2L (BGK) (2006)
The following wire connections must be checked for short circuit to B+, Ground (GND) and for open circuit
-
Check all wires for short circuit to each other.
Specified value: infinite ohms (no continuity)
-
If voltage supply and wire connections are OK, replace Mass Air Flow (MAF) sensor.
-
Read readiness code => [ Readiness Code, Reading ] See: Computers and Control Systems/Testing and Inspection/Monitors, Trips, Drive Cycles
and Readiness Codes .
If DTC memory was erased, readiness code must be generated again => [ Readiness Code, Generating ] See: Computers and Control Systems/Testing
and Inspection/Monitors, Trips, Drive Cycles and Readiness Codes.