audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 6569 > < Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 6567
Page 1
background image

Oxygen Sensor: Testing and Inspection
Heater For Oxygen Sensors After Catalytic Converter, Checking

Heater for Oxygen Sensors after Catalytic Converter, Checking

Component location => [ Heater for Oxygen Sensor before Catalytic Converter, Checking ].

Oxygen sensor signals are monitored via On Board Diagnostic (OBD). 

-

Check DTC memory. If an oxygen sensor malfunction relating to heating circuit is displayed.

-

Disconnect respective harness connector for oxygen sensor (connector strip bolted to underside of transmission).

2

4-pin harness connector for Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) and Oxygen Sensor (O2S) Heater 1
(Z29) behind catalytic converter, bank 1

3

4-pin harness connector for Oxygen Sensor (O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131) and Oxygen Sensor (O2S) Heater 2
(Z30) behind catalytic converter, bank 2

-

Perform continuity test (resistance measurement) between terminals 1 and 2 of respective sensor connector using portable multimeter (VAG1526).

Specified value at room temperature: 1 to 20 ohms

‹› At higher temperatures, resistance climbs sharply.

If specified value is not reached, replace respective Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130)/Oxygen Sensor
(O2S) 2 Behind Three Way Catalytic Converter (TWC) (G131).

If the specified value is obtained, check voltage supply of oxygen sensor.

Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 6569 > < Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 6567