Oxygen Sensor: Testing and Inspection
Oxygen Sensor After Catalytic Converter, Checking Function

Oxygen Sensor after Catalytic Converter, Checking Function

‹› When servicing terminals in harness connector of oxygen sensor, use only gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Multimeter (VAG1526) or Multimeter (VAG1715)

‹› Connector test kit (VAG1594)

‹› Wiring diagram

Test Prerequisites

‹› The respective fuses of Oxygen Sensor (O2S) Behind Three Way Catalytic Converter (TWC) (G130) and Oxygen Sensor (O2S) 2 Behind Three

Way Catalytic Converter (TWC) (G131) must be OK: 

‹› Battery voltage must be at least 12.5 volts.

‹› Oxygen sensor heaters for oxygen sensors behind catalytic converter must be OK (no DTC entry).

‹› All electrical consumers such as, lights and rear window defroster must be switched off.

‹› Parking brake must be engaged or else daylight driving lights will be switched on.

‹› If vehicle is equipped with an A/C system, it must be switched off. 

‹› Ground (GND) connections between engine and chassis must be OK.

‹› Exhaust system must be properly sealed between catalytic converter and cylinder head.

Function Test

-

Coolant temperature must be at least 80 °C => [ Diagnostic Mode 01 - Read Current System Data ] See: Computers and Control Systems/Testing
and Inspection/Scan Tool Testing and Procedures/Diagnostic Modes 01 - 09, Diagnostic mode 1: Check measured values; PID 5, Coolant
temperature.

-

Select the following output of oxygen sensor signals and check whether the specified values are being reached => [ Diagnostic Mode 05 - Read
Oxygen Sensor Monitoring Test Results ] See: Computers and Control Systems/Testing and Inspection/Scan Tool Testing and
Procedures/Diagnostic Modes 01 - 09, Diagnostic mode 5: Check output of oxygen sensor signals.

-

Check specified values of the output of oxygen sensor signals at idle:

 *) V = Voltage in Volts (oxygen sensor signal)