audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 3394 > < Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 3392
Page 1
background image

Oxygen Sensor: Testing and Inspection
Oxygen Sensor Before Catalytic Converter, Checking Function

Oxygen Sensor before Catalytic Converter, Checking Function

‹› When servicing terminals in harness connector of oxygen sensor, use only gold-plated terminals.

Special tools, testers and auxiliary items required

‹› Multimeter (VAG1526) or Multimeter (VAG1715)

‹› Connector test kit (VAG1594)

‹› Wiring diagram

Test Prerequisites

‹› The respective fuses of Heated Oxygen Sensor (HO2S) (G39) and Heated Oxygen Sensor (HO2S) 2 (G108) must be OK: 

‹› Battery voltage must be at least 11.5 volts.

‹› Oxygen sensor heaters for oxygen sensors before catalytic converter must be OK (no DTC entry).

‹› All electrical consumers such as, lights and rear window defroster must be switched off.

‹› Parking brake must be engaged or else daylight driving lights will be switched on.

‹› If vehicle is equipped with an A/C system, it must be switched off. 

‹› Ground (GND) connections between engine and chassis must be OK.

‹› Exhaust system must be properly sealed between catalytic converter and cylinder head.

Function Test

-

Coolant temperature must be at least 80°C => [ Diagnostic Mode 01 - Read Current System Data ] See: Powertrain Management/Computers and
Control Systems/Testing and Inspection/Scan Tool Testing and Procedures/Diagnostic Modes 01 - 09, Diagnostic mode 1: Check measured
values; PID 5, Coolant temperature.

-

Select the following output of oxygen sensor signals and check whether the specified values are being reached => [ Diagnostic Mode 05 - Read
Oxygen Sensor Monitoring Test Results ] See: Powertrain Management/Computers and Control Systems/Testing and Inspection/Scan Tool
Testing and Procedures/Diagnostic Modes 01 - 09, Diagnostic mode 5: Check output of oxygen sensor signals.

-

Check specified values of the output of oxygen sensor signals at idle:

*) V = Voltage in Volts (oxygen sensor signal)

Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 3394 > < Heater For Oxygen Sensor Before Catalytic Converter, Checking|Page 3392