audi Workshop Repair Guides

Audi Workshop Service and Repair Manuals

Control Assembly, HVAC > < Condenser|Page 8631
Page 2
background image

-

Replace O-ring seals - B - and - C -. Version. 

‹› Coat O-ring seals lightly with refrigerant oil before installing. Refer to => [ Refrigerant Circuit O-Ring Seals ] See: Description and

Operation/Refrigerant Circuit O-Ring Seals.

-

Following attachment, check routing of refrigerant pipes. They must be inserted in holders provided and not make contact with other components. 

-

Evacuate and re-charge refrigerant circuit. 

-

Operate the A/C system after filling the refrigerant circuit. Refer to => [ Operating A/C System after Filling Refrigerant Circuit ] See: Description
and Operation/Operating A/C System after Filling Refrigerant Circuit

‹› Note the information regarding operating the A/C system after filling.

Control Assembly, HVAC > < Condenser|Page 8631