A8 Quattro Sedan V8-4.2L (BVJ) (2008)
-
Install refrigerant pipes such that they are not strained.
-
Tighten threaded connection - A - to 15 Nm.
‹› Check position of refrigerant pipes after tightening union. Pipes must not make contact with other components.
-
Evacuate and re-charge refrigerant circuit.
-
Operate the A/C system after filling the refrigerant circuit. Refer to => [ Operating A/C System after Filling Refrigerant Circuit ] See: Description
and Operation/Operating A/C System after Filling Refrigerant Circuit
‹› Note the information regarding operating the A/C system after filling.